| Technical data |
| Functional Principle | Piston pump |
| Lubricant Volume (VLub) |
400 / 800 cm³
|
| Metering Quantity (per Outlet and Stroke/Impulse) |
0.15 cm³
|
| Operating Pressure, Maximum (pop) |
70 bar
|
| Lubricant |
≤ NLGI 3 (suitability test required)
|
| Number of Pump Bodies (npb) |
4
|
| Number of Outlets (nout) |
4
|
| Number of Lubrication Points: Direct |
≤ 4
|
| Connection |
PA hose
|
| Operating Voltage (Uop) |
DC 24 V or 6-V alkaline battery
|
| Connection Plug for Multi-Function Interface |
—
|
| Controller (Integrated) |
OPTIME
|
| Controller (Extern) |
—
|
| Monitoring: Pressure |
via OPTIME
|
| Monitoring: Fill level |
via OPTIME
|
| Error Message |
Empty level, back pressure, internal error: via OPTIME
|
| Protection Class |
IP68
|
| Housing Material |
Polyamide
|
| Operating Temperature, Minimum (tmin) |
-20 °C
|
| Operating Temperature, Maximum (tmax) |
70 °C
|
| Mounting Position |
vertical
|
| Dimensions (mm) |
297 x 144 x 144
|
| Weight (≈m) |
2.603 kg
|